How do you wire a Rex?

Wiring a REX / REX Button

  1. Connect and power the LED on your REX motion device. Connect the + and – on the REX using a 12/24V power supply.
  2. Connect circuit signal wires to Common and Normally Closed.
  3. Connect and power the REX.

Can you wire a PIR to any light?

You can connect it to any type of decorative fixture—even existing ones—and mount it discreetly off to the side. This article will show you how to install and connect a remote sensor to new or existing lights.

Is a Rex normally open or closed?

Note: The REX relay Common to Normally Open and Common to Normally Closed contacts will reverse when changing from Fail Safe to Fail Secure mode.

Is a mag lock normally closed?

After leaving the control panel, the mag lock positive feed is terminated to the common on 1 relay in the motion sensor. Power is continuous in and out of the motion. The button is Normally Closed. It also transfers continuous power to the mag lock positive wire.

Can I run one light off 2 PIR sensors?

Hi, In theory-yes-using 3 core (plus cpc), any one pir activating will bring all the lights on-bearing in mind the total load!,most pir’s will switch up to 1000 watts, so dependent you may require a relay. If the pir’s (or at least one of them) has manual overide then it will work. Richard.

Can you 2 way a sensor?

This sensor is ideal where two way switching is required with pir movement sensors, top and bottom of stairs / each side of a room or corridor etc. Sensor can be paired wirelessly with another sensor. As one triggers it will automatically trigger other paired sensor.

Can you put 2 motion lights on the same circuit?

Generally speaking, two lights on the same switch will turn on and off at the same time. If they are both off then the one with the motion detector will not operate since there is no line voltage to the light.

What wire is used for alarm system?

The recommend gauge wire for alarm components is solid or stranded 22 AWG, 2 conductor wire (black and red) or 22 AWG, 4 conductor wire ( black, red, green and yellow or white). Solid copper wire does not bend as easily as stranded wire, but eliminates the chance of a loose strand of wire causing a short.

How to wire a wired PIR motion detector?

Wiring the wired PIR motion detector 1 Open the cover of your PIR Motion Detector, then typically you will see the main-board as below: TAMPER: This is a tamper protection for wired PIR. 2 Wiring the cable from alarm panel. a. 3 What’s the EOL Resistor?

What is the power supply of PIR motion sensor?

+12V GND: This is the power supply of PIR Motion Sensor, you can either connect to DC power from AC/DC adapter or connect to +12V output of alarm panel. With the power supply of +12V, then the PIR can not work. Normally PIR can work wide-range DC power from 9V to 16V.

How to connect Pir to the alarm panel?

ALARM: This is the alarm output for PIR, it can provide N.O. (Normal Open) or N.C. (Normal Close) signal to alarm panel. (Herein For VS-YH400, The default setting is N.C (Normal Close) output. 2. Wiring the cable from alarm panel. a. Using cables (wires) connect the tamper to one of zones of alarm panel (This is an optional connection). b.

Which wire is positive on an alarm system?

(Normally, Red wire is positive (+12V), Black wire is Negative (GND). c. Using cables (wires) connect the ALARM to one of zones of alarm panel. Connection for tamper and power are fixed for wired PIR and most of wired sensors.